Excessive Hub Bearing Bore Clearance in a Cooling Tower Fan Causes Vibration

E43-144 · Improper Clearance Fit · Cooling Tower Fan · ★

Problem Symptom

The Φ90 hub bearing bore was designed with 0.01mm interference but measured 0.04mm clearance; vibration reached 4.5mm/s

Root Cause

[Fit Changed to Clearance] The H7/r6 interference of 0.01mm was designed, but the oversize bore turned it into a 0.04mm clearance.
[Vibration] The loose outer ring gave unbalanced vibration of 4.5mm/s, above the limit.
[Design Omission] The H7/r6 interference should have been controlled with the bore measured, but the clearance was left in place.

Correct Solution

1) Change to an H7/r6 interference of 0.01mm;
2) Control the bore to the lower limit;
3) Inspect the bearing bore on a CMM;
4) Measure the vibration value;
5) Verify the vibration against the looseness;
6) Dynamically balance;
7) Re-tighten periodically;
8) Spot-check every batch.