Excessive Clearance Between the Seal Sleeve and the Shaft Causes Leakage

E43-145 · Improper Clearance Fit · Chemical Process Pump Mechanical Seal · ★★

Problem Symptom

The clearance between the seal sleeve and the shaft was designed at 0.02mm but measured 0.08mm; the medium leaked along the sleeve

Root Cause

[Large Clearance] The design clearance was 0.02mm, but corrosion of the sleeve bore opened it up so the actual clearance reached 0.08mm.
[Leakage] With the large clearance the medium leaked out along the sleeve and contaminated the environment.
[Design Omission] The clearance should have been controlled to ≤0.03mm with an O-ring provided, but corrosion was not controlled.

Correct Solution

1) Control the clearance to ≤0.03mm;
2) Protect the sleeve bore against corrosion;
3) Fit an O-ring;
4) Carry out a leakage check;
5) Verify the seal against the clearance;
6) Harden the shaft;
7) Replace the sleeve regularly;
8) Spot-check every batch.

Checklist

References

GB/T 1801-2009 Limits and Fits