Excessive Gate-to-Seat Clearance in a Gate Valve Causes Internal Leakage

E43-146 · Improper Clearance Fit · Pipeline Gate Valve · ★

Problem Symptom

The clearance between the gate and the seat was designed at 0.05mm but measured 0.20mm; internal leakage caused a loss of pressure

Root Cause

[Large Clearance] The design clearance was 0.05mm, but erosion of the seat made the actual clearance 0.20mm.
[Internal Leakage] With the large clearance the valve could not shut off, the medium leaked and the pressure was lost.
[Design Omission] The clearance should have been controlled to ≤0.06mm with the seat hard faced, but erosion was not controlled.

Correct Solution

1) Control the clearance to ≤0.06mm;
2) Hard face the valve seat;
3) Guide the gate;
4) Perform a seat leakage test;
5) Verify the leakage against the clearance;
6) Grind the seat periodically;
7) Filter the medium;
8) Check the tightness every batch.