E43-151 · Interference Fit Failures · 2MW Wind Turbine Gearbox Rotor Shaft ∅220, designed interference 0.18mm, measured only 0.06mm · ★★★
The rotor transmitted 12kNm of torque; the insufficient interference let the mating surfaces slip and the rotor moved 8mm axially out of the shaft
[Mechanism] The insufficient interference drove the contact pressure on the mating surfaces below the level needed for friction torque transmission, and after fretting wear it slipped completely.
[Calculation] The required contact pressure is p≥2T/(πd²Lμ)=2×12e3/(π×0.22²×0.18×0.12)=16.3MPa, but the measured δ=0.06mm corresponds to p=7.1MPa, which is insufficient.
[Design Omission] Only ∅220H7/s6 was specified with no upper and lower press force limits and no anti-loosening key; this design flaw allowed the hub to slip and come off in service.
1) Raise the interference to 0.18~0.22mm;
2) Control the press force to 120~150t;
3) Add an interference fit plus key as a double safeguard;
4) Assemble with the shaft chilled in liquid nitrogen at -20℃;
5) Re-check with a torque wrench;
6) Measure the axial displacement every shift;
7) Perform magnetic particle inspection of the inner ring;
8) Carry out a pull-out test on the first piece of ≥150kN.
GB/T 5371-2004 Interference Fits — Calculation and Selection