Insufficient Gear-to-Shaft Interference Causes Fretting Wear on the Tooth Flank

E43-153 · Interference Fit Failures · Mining Gearbox Pinion ∅90, designed interference 0.07mm, measured 0.03mm · ★★

Problem Symptom

The gear transmitted 2.1kNm of torque; the insufficient interference produced fretting wear and the tooth flank spalled

Root Cause

[Mechanism] The insufficient interference allowed slight sliding of the mating surfaces under alternating torque, and the accumulated oxidised wear debris accelerated the wear.
[Calculation] The required p≥2T/(πd²Lμ)=2×2.1e3/(π×0.09²×0.11×0.12)=12.5MPa, but the measured δ=0.03 corresponds to p=4.0MPa, which is insufficient.
[Design Omission] The gear-to-shaft fit was not specified as H7/r6 and no axial locating pin was provided; this design flaw caused fretting wear and spalling.

Correct Solution

1) Raise the interference to 0.07~0.10mm;
2) Select H7/r6;
3) Add an end-face locating pin;
4) Control the press force to 35~45t;
5) Keep the tooth flank hardness difference at ≥HRC5;
6) Analyse the oil by ferrography;
7) Monitor vibration;
8) Disassemble and inspect the first piece.