E43-154 · Interference Fit Failures · Fan Pulley ∅65, designed interference 0.05mm, measured 0.02mm · ★★
The pulley transmitted 0.9kNm of torque; the insufficient interference caused slipping and the fan airflow fell 15%
[Mechanism] The insufficient interference left the friction torque below the load, so slipping occurred whenever the belt tension fluctuated.
[Calculation] The required p≥2T/(πd²Lμ)=2×0.9e3/(π×0.065²×0.09×0.15)=10.0MPa, but the measured δ=0.02 corresponds to p=3.3MPa, which is insufficient.
[Design Omission] Only ∅65H7/m6 was specified with no press process and no set screws; this design flaw caused slipping.
1) Raise the interference to 0.05~0.07mm;
2) Add 2 set screws;
3) Control the press force to 18~25t;
4) Select H7/n6;
5) Calibrate the belt tension;
6) Measure the speed difference;
7) Specify surface roughness Ra0.8;
8) Check the torque on the first piece.
GB/T 5371-2004 Interference Fits — Calculation and Selection