MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Tolerance & Fit Error Cases › Insufficient Coupling-to-S
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Insufficient Coupling-to-Shaft Interference Causes Axial Migration

E43-155 · Interference Fit Failures · Pump Elastomer Coupling ∅80, designed interference 0.06mm, measured 0.025mm · ★★

Problem Symptom

The coupling transmitted 1.5kNm of torque; the insufficient interference allowed 3mm of axial migration and the seal failed, leaking oil

Root Cause

[Mechanism] The insufficient interference allowed the mating surfaces to creep and migrate under the axial force, destroying the alignment.
[Calculation] The required p≥2T/(πd²Lμ)=2×1.5e3/(π×0.08²×0.10×0.12)=12.4MPa, but the measured δ=0.025 corresponds to p=4.1MPa, which is insufficient.
[Design Omission] No shaft shoulder axial stop and no lock nut were provided; this design flaw allowed axial movement.

Correct Solution

1) Raise the interference to 0.06~0.09mm;
2) Add a shaft shoulder as an axial stop;
3) Fit a lock nut;
4) Control the press force to 30~40t;
5) Re-check the alignment;
6) Measure the vibration velocity ≤4.5mm/s after installation to verify smooth running;
7) Check for oil leakage;
8) Carry out a pull-out test on the first piece.

Checklist

References

GB/T 5371-2004 Interference Fits — Calculation and Selection

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL