E43-160 · Interference Fit Failures · Stamping Press Flywheel ∅280, designed interference 0.22mm, measured 0.09mm · ★★★
The flywheel stored 26kNm of torque; the insufficient interference loosened it under impact and it came off, with a risk of fragmentation
[Mechanism] The insufficient interference let the flywheel slide under cyclic impact torque, the movement accumulated and it eventually came off.
[Calculation] The required p≥2T/(πd²Lμ)=2×26e3/(π×0.28²×0.18×0.11)=18.7MPa, but the measured δ=0.09 corresponds to p=6.4MPa, which is insufficient.
[Design Omission] No interference fit plus tangent key double safeguard was provided and the impact speed was not limited; this design flaw created a fragmentation risk.
1) Raise the interference to 0.22~0.27mm;
2) Add tangent keys;
3) Limit the impact speed;
4) Hot assemble at 250℃;
5) Dynamically balance;
6) Measure by ultrasonic testing;
7) Fit guarding;
8) Carry out a pull-out test on the first piece of ≥300kN.
GB/T 5371-2004 Interference Fits — Calculation and Selection