E43-161 · Interference Fit Failures · Grinding Machine Spindle Bearing ∅70, designed interference 0.02mm, measured 0.06mm · ★★★
The interference was 3 times out of specification; the circumferential tensile stress in the inner ring reached 380MPa and exceeded yield, and after 200 running hours the inner ring cracked longitudinally
[Mechanism] The excessive interference imposed an unduly large circumferential tensile stress on the inner ring and stress concentration at the fit initiated a crack.
[Calculation] The inner ring tensile stress σ=p·d/(2t)=p×70/(2×8), with p=δE/d=0.06×2.1e5/70=180MPa, giving σ=788MPa, above the material yield strength.
[Design Omission] No upper deviation limit was given for the interference and the shaft diameter upper limit was not controlled; this design flaw caused the inner ring fracture.
1) Control the interference to 0.018~0.025mm;
2) Control the upper limit of the shaft diameter;
3) Select k5;
4) Assemble with the shaft chilled to -15℃;
5) Inspect the inner ring by NDT;
6) Measure the vibration velocity ≤2.8mm/s after installation to verify smooth running;
7) Set a temperature rise limit;
8) Check the stress on the first piece.
GB/T 307.3-2017 Rolling Bearings — General Technical Rules