E43-163 · Interference Fit Failures · Pulley Hub ∅120, designed interference 0.05mm, measured 0.14mm · ★★★
The excessive interference brought the hoop tensile stress in the cast iron hub to 210MPa, above its tensile strength, and the hub cracked longitudinally
[Mechanism] The excessive interference put an unduly large hoop tensile stress on the brittle hub and it cracked once the tensile strength was exceeded.
[Calculation] The hub tensile stress σ=p·d²/(D²-d²)=p×120²/(200²-120²), with p=0.14×1.2e5/120=140MPa, giving σ=207MPa, above the tensile strength of HT250.
[Design Omission] The hub strength was not checked and the upper interference limit was not set; this design flaw cracked the hub.
1) Control the interference to 0.045~0.060mm;
2) Check the hub strength;
3) Select a nodular iron QT grade;
4) Limit the press force;
5) Perform magnetic particle inspection;
6) Use acoustic emission monitoring;
7) Control the temperature during assembly;
8) Carry out a press-to-break test on the first piece.
GB/T 5371-2004 Interference Fits — Calculation and Selection