E43-164 · Interference Fit Failures · Motor End Cap Bearing Bore ∅150, hot assembly specified at 200℃ but measured only 120℃ · ★★
The insufficient hot-assembly temperature gave only 0.13mm of bore expansion against a 0.20mm interference, so after cooling the parts did not grip and loosened
[Mechanism] Insufficient heating made the thermal expansion of the female part smaller than the interference, so it could not be fitted properly and was forced in, causing damage.
[Calculation] The required expansion Δ=αLΔT=12e-6×150×ΔT≥0.20 needs ΔT≥111℃, that is ≥131℃; the measured 120℃ gave only Δ=0.13mm, which is insufficient.
[Design Omission] The minimum heating temperature and the temperature measuring point were not specified; this design flaw prevented the parts gripping.
1) Heat to ≥200℃ and hold for 30min;
2) Attach the temperature sensor to the part;
3) Calculate the expansion;
4) Heat the sleeve and fit it quickly;
5) Inspect after cooling;
6) Re-check the torque;
7) Use an infrared thermometer;
8) Measure the expansion on the first piece.
GB/T 5371-2004 Interference Fits — Calculation and Selection