E43-168 · Interference Fit Failures · Spindle ∅110, hydraulic removal pressure 350MPa against a design limit of 250MPa · ★★
The excessive removal oil pressure drove oil into microscopic cracks so the mating surfaces blistered and flaked
[Mechanism] The injection pressure far exceeded the contact pressure, so oil was forced into surface defects and the metal blistered and peeled.
[Calculation] The contact pressure p0=δE/d=0.10×2.1e5/110=191MPa, and the measured 350MPa is 1.8 times higher, producing oil-wedge splitting.
[Design Omission] The upper limit on removal pressure was not set and the oil viscosity was not controlled; this design flaw damaged the surfaces.
1) Control the pressure to ≤250MPa;
2) Set an upper limit;
3) Control the oil viscosity;
4) Raise the pressure gradually;
5) Inspect the mating surfaces visually after removal;
6) Polish and repair scored surfaces;
7) Carry out NDT to check for cracks;
8) Carry out a removal test on the first piece.
GB/T 5371-2004 Interference Fits — Calculation and Selection