❌ Error Case Studies

📚 Technical Articles

Insufficient Hydraulic Removal Pressure Prevents Withdrawal

E43-167 · Interference Fit Failures · Rolling Mill Roll Shaft ∅200, hydraulic removal pressure 30MPa but measured only 12MPa · ★★

Problem Symptom

The insufficient removal oil pressure left the mating surfaces undecompressed, and forcing the part out scored the shaft surface

Root Cause

[Mechanism] The injection pressure did not exceed the contact pressure, so no oil film formed, the static friction was not overcome and the part could not be withdrawn.
[Calculation] The injection pressure must be p≥the contact pressure p0=δE/d=0.18×2.1e5/200=189MPa to unload the fit; the measured 12MPa is far short.
[Design Omission] No injection hole or pressure class was designed and no removal force curve was given; this design flaw caused scoring.

Correct Solution

1) Use an injection pressure of ≥200MPa;
2) Provide an injection hole;
3) Provide the removal force curve;
4) Use dedicated tooling;
5) Ramp the pressure slowly after injection to withdraw without damage;
6) Inspect the mating surfaces visually after removal;
7) Grind and repair damaged areas;
8) Carry out a removal test on the first piece.

Checklist