E43-166 · Interference Fit Failures · Worm Shaft ∅90, hot assembly at 420℃ but measured 520℃ · ★★
The excessive hot-assembly temperature tempered and softened the quenched and tempered shaft; the hardness fell from HRC32 to HRC22 and the mating surface was crushed
[Mechanism] Heating above the tempering temperature caused secondary tempering and softening of the shaft material, the yield strength dropped and the fit failed.
[Calculation] The quenching and tempering temperature was 320℃; heating to 520℃ exceeded it by 200℃ and softened the structure, dropping the hardness by 10HRC and reducing the allowable p by 30%.
[Design Omission] No upper limit on the heating temperature and no overtemperature alarm were provided; this design flaw caused annealing and softening.
1) Control the heating to ≤300℃;
2) Fit an overtemperature alarm;
3) Select a high temperature resistant steel;
4) Use a temperature measuring gun;
5) Re-check the hardness;
6) Time the heating process to prevent overtemperature annealing;
7) Carry out NDT after hot assembly to check for cracks;
8) Measure the hardness on the first piece.
GB/T 5371-2004 Interference Fits — Calculation and Selection