📚 Technical Articles

Miscalculated Axial Press-In on a Taper Causes Insufficient Cone Interference

E43-170 · Interference Fit Failures · Marine Stern Tube Cone ∅120, taper 1:15, axial press-in miscalculated by 8mm too little · ★★

Problem Symptom

The insufficient axial press-in left only 0.04mm of cone interference against the 0.10mm required, and the part loosened during operation

Root Cause

[Mechanism] The axial press-in amount determines the cone interference, and the miscalculation left the actual interference too small to transmit torque.
[Calculation] The interference is δ=axial press-in×taper/2; for δ=0.10 the axial press-in must be 0.10×2×15=3.0mm; the 8mm shortfall left δ=0.04, which is insufficient.
[Design Omission] No axial press-in table and no feeler gauge control were provided; this design flaw caused loosening.

Correct Solution

1) Recalculate the axial press-in amount;
2) Provide a press-in table;
3) Control with a feeler gauge;
4) Use a hydraulic nut;
5) Tighten the hydraulic nut with a torque wrench;
6) Mark alignment lines before pressing to prevent offset;
7) Disassemble the first piece and check the press-in amount;
8) Carry out a pull-out test on the first piece.

Checklist

References

GB/T 157-2001 Tapers and Taper Angles — Series