Wrong Tolerance Zone Selection Causes a Loose Sprocket Fit

E43-175 · Interference Fit Failures · Sprocket ∅50, specified H7/s6 but measured mostly at the lower limit of H7/r6 and too loose · ★★

Problem Symptom

The tolerance zone selection made the actual interference frequently fall to the 0.02mm lower limit, and the sprocket slipped

Root Cause

[Mechanism] For s6 the upper deviation is 0.059 and the lower deviation 0.043; if the shaft is machined at the low end the interference is only 0.02, which is too small.
[Calculation] An interference of ≥0.04 is needed to transmit 0.6kNm, but the measured 0.02 gives p=0.02×2.1e5/50=84MPa, which is insufficient.
[Design Omission] The fit was not reselected as u6 based on the load and no mean interference was given; this design flaw made the fit loose.

Correct Solution

1) Reselect as H7/u6;
2) Set the mean interference to 0.05;
3) Machine the shaft at mid-tolerance;
4) Control the press force;
5) Inspect the torque;
6) Group and select parts by the measured sizes;
7) Mark the matched pairs to prevent wrong assembly;
8) Check the torque on the first piece.

Checklist

References

GB/T 1800.2-2020 Geometrical Product Specifications (GPS)