Thermal Cycling Loosens a Bimetal Aluminium Housing-to-Steel Shaft Fit

E43-174 · Interference Fit Failures · Servo Motor Aluminium Housing ∅40 with Steel Shaft, interference 0.05mm, loosened after thermal cycling · ★★

Problem Symptom

The aluminium housing expanded more than the steel during thermal cycling so the interference disappeared and the rotor swept the bore

Root Cause

[Mechanism] The aluminium expansion coefficient 23e-6 is far greater than the steel 11e-6, so the temperature rise substantially reduced the interference.
[Calculation] Δinterference=(αaluminium-αsteel)LΔT=(23-11)e-6×40×80=0.038mm, so the original 0.05 became 0.012, which is insufficient.
[Design Omission] No thermal cycle interference compensation was made and no steel liner was inserted into the aluminium; this design flaw caused loosening.

Correct Solution

1) Raise the interference to 0.08mm;
2) Fit a steel liner;
3) Compensate for the thermal cycle;
4) Select H7/n6;
5) Monitor the temperature with a thermometer;
6) Carry out NDT after thermal cycling to check for cracks;
7) Re-tighten the locking parts after thermal cycling;
8) Carry out a thermal cycle test on the first piece.