E43-178 · Interference Fit Failures · Gear ∅75, press misalignment 0.15mm, shaft surface galled to Ra3.2 · ★★
The misaligned pressing caused local galling of the mating surface, the contact pressure became uneven and the fit loosened
[Mechanism] Pressing not perpendicular skewed the shaft and bore axes and the local contact stress became excessive, galling the surfaces.
[Calculation] A misalignment of 0.15mm over 75 changed the single-side clearance and doubled the local contact pressure, exceeding yield and causing galling to Ra3.2.
[Design Omission] No press guidance or perpendicularity check was provided; this design flaw caused galling.
1) Add a guide sleeve;
2) Keep perpendicularity ≤0.02;
3) Keep the press force steady;
4) Inspect the surface Ra;
5) Group and select parts by the measured sizes;
6) Lap to guarantee the guiding face seats properly;
7) Carry out NDT after assembly to check for cracks;
8) Carry out a guide trial on the first piece.
GB/T 5371-2004 Interference Fits — Calculation and Selection