Wrong Gauge Use Misjudges the Interference and the Fit Loosens

E43-179 · Interference Fit Failures · Shaft ∅40 checked with a plug gauge, actual interference 0.02mm judged as acceptable · ★★

Problem Symptom

Misuse of the go/no-go gauge let the undersize shaft diameter go undetected; the actual interference was only 0.02mm and it slipped

Root Cause

[Mechanism] The wrong gauge caused the shaft diameter at mid-tolerance to be misjudged, and the interference at the lower limit was still released.
[Calculation] An interference of ≥0.04 is needed to transmit 0.5kNm, but the measured 0.02 gives p=0.02×2.1e5/40=105MPa, which is insufficient.
[Design Omission] The interference was not required to be measured on a CMM and only plug gauges were relied upon; this design flaw caused a misjudged loose fit.

Correct Solution

1) Measure the diameter on a CMM;
2) Measure the actual interference;
3) Select the fit correctly;
4) Calibrate the gauges;
5) Inspect the torque;
6) Carry out dimensional and torque inspection on the first piece;
7) Check the nominal fit values;
8) Re-measure the critical dimensions.

Checklist

References

GB/T 1957-2017 Plain Limit Gauges