E43-181 · Interference Fit Failures · Hub ∅130, mating surface Ra6.3 too rough, actual interference lost 0.05mm · ★★
The rough surface had its microscopic peaks crushed during pressing, consuming the interference so that the torque transmission was insufficient and it slipped
[Mechanism] On a too-rough surface the microscopic peaks were crushed flat during pressing, reducing the effective interference by tens of microns.
[Calculation] At Ra6.3 the peak height is about 0.025mm, so 0.05mm was lost on both sides, leaving 0.10 from the designed 0.15 and reducing p by 33%.
[Design Omission] The mating surface roughness was not specified as Ra≤1.6; this design flaw caused the pressure drop.
1) Specify roughness Ra≤1.6;
2) Compensate the interference;
3) Pre-treat the surfaces;
4) Control the press force;
5) Tighten the locking parts to the specified torque;
6) Inspect the surface quality after pressing;
7) Group and select parts by the measured sizes;
8) Carry out a press test on the first piece.
GB/T 5371-2004 Interference Fits — Calculation and Selection