Fatigue Micro-Cracks Grow in an Interference Fit under Alternating Load

E43-182 · Interference Fit Failures · Crankshaft Gear ∅85, interference 0.06mm, micro-cracked under alternating load · ★★

Problem Symptom

Long-term alternating torque initiated fatigue micro-cracks at the edge of the interference joint and the gear ring loosened

Root Cause

[Mechanism] The alternating load repeatedly varied the stress amplitude at the edge of the joint, exceeding the fatigue limit and initiating cracks.
[Calculation] The edge stress amplitude σa=Kt·p/2=2.2×0.06×2.1e5/85/2=163MPa, above the material fatigue limit of 140MPa.
[Design Omission] No fatigue strength check was made and the stress amplitude was not limited; this design flaw caused micro-cracking.

Correct Solution

1) Carry out a fatigue check;
2) Reduce the interference to 0.05;
3) Round the stress concentration point to R3;
4) Limit the maximum load to prevent overload;
5) Carry out NDT to check for cracks;
6) Use acoustic emission monitoring;
7) Re-tighten the locking parts periodically;
8) Carry out a fatigue test on the first piece.

Checklist

References

GB/T 5371-2004 Interference Fits — Calculation and Selection