Shaft Current Erosion Loosens the Interference Fit

E43-183 · Interference Fit Failures · Inverter Motor Shaft ∅65, shaft current pitting, mating surface pitted and loosened · ★★

Problem Symptom

Shaft current discharge pitted the surface so the effective contact area fell and the rotor loosened

Root Cause

[Mechanism] The shaft voltage broke down the oil film and discharged, and the pits reduced the actual contact area so the interference was lost.
[Calculation] The pits were 0.02mm deep over 15% of the area, reducing the effective p by 15% so the torque transmission was insufficient and it slipped.
[Design Omission] No bearing insulation and no grounding were provided; this design flaw caused electrical erosion and loosening.

Correct Solution

1) Insulate the bearings;
2) Ground the shaft;
3) Compensate the interference;
4) Inspect the mating surface visually;
5) Measure the insulation;
6) Take an oil sample for wear analysis;
7) Re-tighten periodically;
8) Carry out an electrical test on the first piece.

Checklist

References

GB/T 5371-2004 Interference Fits — Calculation and Selection