MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Tolerance & Fit Error Cases › Insufficient Gear Pump Rot
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Insufficient Gear Pump Rotor-to-Shaft Interference Causes Internal Leakage

E43-184 · Interference Fit Failures · Gear Pump Rotor ∅30, designed interference 0.02mm, measured 0.008mm · ★★

Problem Symptom

The insufficient interference let the rotor micro-move and the internal cavity short-circuit, cutting volumetric efficiency by 11%

Root Cause

[Mechanism] The insufficient interference let the rotor micro-move under the pressure difference and the high and low pressure cavities connected, causing internal leakage.
[Calculation] Even at low torque p≥2T/(πd²Lμ) requires δ≥0.015; the measured 0.008 was insufficient and caused micro-motion.
[Design Omission] The fit was not selected as H7/s6 and no locking was provided; this design flaw caused internal leakage.

Correct Solution

1) Raise the interference to 0.02~0.03;
2) Select H7/s6;
3) Add axial locking to prevent it coming off;
4) Assemble cold on a press to guarantee the interference;
5) Check the volumetric efficiency;
6) Group and select parts by the measured sizes;
7) Apply rust protection to the mating surfaces;
8) Carry out a leakage test on the first piece.

Checklist

References

GB/T 5371-2004 Interference Fits — Calculation and Selection

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL