E43-185 · Interference Fit Failures · Compressor Connecting Rod Small End Bushing ∅25, designed interference 0.015mm, measured 0.005mm · ★★
The insufficient interference made the bushing rattle and knock, and the connecting rod was scrapped
[Mechanism] The insufficient interference let the bushing loosen under the alternating force and knock against the bore.
[Calculation] δ≥0.012 is needed to transmit the small torque; the measured 0.005 gives p=0.005×2.1e5/25=42MPa, which is insufficient and allowed loosening.
[Design Omission] The bushing interference was not controlled and pressing was not required to bottom out; this design flaw caused knocking.
1) Raise the interference to 0.015~0.02;
2) Press fully home;
3) Select H7/n6;
4) Carry out NDT after pressing to check for cracks;
5) Judge seating by the assembly sound;
6) Group and select parts by the measured sizes;
7) Re-press to guarantee full seating;
8) Carry out a sound test on the first piece.
GB/T 5371-2004 Interference Fits — Calculation and Selection