Insufficient Pump Impeller-to-Shaft Interference Intensifies Cavitation

E43-186 · Interference Fit Failures · Centrifugal Pump Impeller ∅45, designed interference 0.03mm, measured 0.01mm · ★★

Problem Symptom

The insufficient interference made the impeller micro-move so the wear ring clearance became uneven, cavitation worsened and efficiency fell 9%

Root Cause

[Mechanism] The insufficient interference let the impeller wobble, and the single-side wear ring clearance opened up, inducing cavitation.
[Calculation] δ≥0.025 is needed to steady the impeller; the measured 0.01 gave 0.02mm of eccentricity and an uneven clearance.
[Design Omission] The impeller interference was not controlled and no dynamic balancing was done; this design flaw caused cavitation.

Correct Solution

1) Raise the interference to 0.03~0.04;
2) Dynamically balance;
3) Inspect the wear ring;
4) Assemble cold on a press to guarantee the interference;
5) Measure the clearance;
6) Group and select parts by the measured sizes;
7) Re-tighten periodically;
8) Carry out a performance test on the first piece.

Checklist

References