Insufficient Pitch Bearing-to-Hub Interference Causes Axial Drift

E43-192 · Interference Fit Failures · Wind Turbine Hub Pitch Bearing ∅320, designed interference 0.12mm, measured 0.05mm · ★★★

Problem Symptom

The insufficient interference made the pitch bearing creep under alternating wind load and the blade angle drifted, reducing power output

Root Cause

[Mechanism] The insufficient interference let the bearing outer ring micro-move and creep under alternating wind load.
[Calculation] The required p≥F/(πdLμ)=600e3/(π×0.32×0.25×0.12)=19.9MPa, but the measured δ=0.05 gives p=3.3MPa, which is insufficient.
[Design Omission] The bearing seat interference was not controlled and no anti-rotation pin was provided; this design flaw caused the axial drift.

Correct Solution

1) Raise the interference to 0.12~0.15;
2) Fit anti-rotation pins;
3) Select H7/p6;
4) Cold assemble the shaft part to guarantee the interference;
5) Check the rotation angle;
6) Carry out NDT after assembly to check for cracks;
7) Re-tighten periodically;
8) Carry out a pull-out test on the first piece.

Checklist

References

GB/T 5371-2004 Interference Fits — Calculation and Selection

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL