Insufficient Bearing-to-Shaft Interference Causes Raceway Flaking in a High-Speed Gearbox

E43-193 · Interference Fit Failures · EMU Gearbox Bearing ∅130, designed interference 0.05mm, measured 0.02mm · ★★★

Problem Symptom

The insufficient interference let the bearing inner ring creep and the raceway was flaked, forcing speed restrictions and repair

Root Cause

[Mechanism] The insufficient interference let the inner ring creep and wear, and the raceway was indented and flaked.
[Calculation] δ≥0.04 is needed to transmit 3kNm; the measured 0.02 gives p=0.02×2.1e5/130=32MPa, which is insufficient and allowed micro-motion.
[Design Omission] The fit was not selected as k5/js6 and the shaft diameter was not controlled; this design flaw caused the flaking.

Correct Solution

1) Control the interference to 0.045~0.055;
2) Select k5;
3) Control the shaft diameter;
4) Assemble with a temperature difference;
5) Carry out NDT after assembly to check for cracks;
6) Monitor the temperature rise during operation to ≤40K;
7) Measure the vibration velocity ≤2.8mm/s;
8) Measure the stress on the first piece.

Checklist

References

GB/T 307.3-2017 Rolling Bearings — General Technical Rules