Insufficient TBM Cutter Head-to-Mainshaft Interference Causes Oscillation

E43-194 · Interference Fit Failures · TBM Cutter Head Connection ∅500, designed interference 0.30mm, measured 0.12mm · ★★★

Problem Symptom

The insufficient interference made the cutter head micro-move and loosen under the huge alternating torque during tunnelling, creating a cutter change risk

Root Cause

[Mechanism] The insufficient interference let the cutter head micro-move and accumulate under the enormous alternating torque until it loosened.
[Calculation] The required p≥2T/(πd²Lμ)=2×120e3/(π×0.5²×0.35×0.13)=6.7MPa, but the measured δ=0.12 gives p=5.0MPa, which is insufficient.
[Design Omission] No hydraulic tensioning was provided and the interference was not controlled; this design flaw caused oscillation.

Correct Solution

1) Raise the interference to 0.30~0.36;
2) Apply hydraulic tensioning;
3) Select H7/u6;
4) Use hydraulic injection;
5) Carry out NDT after assembly to check for cracks;
6) Verify smooth running with a rotation test;
7) Re-tighten periodically;
8) Carry out a pull-out test on the first piece.

Checklist

References

GB/T 5371-2004 Interference Fits — Calculation and Selection