E43-195 · Interference Fit Failures · Injection Moulding Machine Screw Gear ∅90, designed interference 0.06mm, measured 0.02mm · ★★
The insufficient interference made the plasticising gear slip so the back pressure was unstable and the moulded parts were overweight
[Mechanism] The insufficient interference let the gear micro-move and slip under the plasticising reaction torque.
[Calculation] δ≥0.05 is needed to transmit 1.6kNm; the measured 0.02 gives p=0.02×2.1e5/90=47MPa, which is insufficient.
[Design Omission] The fit was not selected as H7/s6 and no locking was provided; this design flaw caused slipping.
1) Raise the interference from 0.02 to 0.06~0.08mm to guarantee torque transmission of ≥1.6kNm;
2) Select the H7/s6 interference tolerance zone to ensure a minimum interference;
3) Add a shaft end nut to lock against axial migration and avoid loosening by micro-motion;
4) Assemble cold on a press at 30~40t so the interference is fully seated;
5) Verify the fit transmits ≥1.6kNm and tighten the locking parts to the specified torque;
6) Group and select parts by the measured bore and shaft sizes so the interference stays within 0.06~0.08;
7) Re-tighten the locking parts after the run-in to prevent creep and micro-motion loosening;
8) Carry out a torque transmission test on the first piece to verify there is no slipping.
GB/T 5371-2004 Interference Fits — Calculation and Selection