Insufficient Winch Drum-to-Shaft Interference Causes Slipping

E43-196 · Interference Fit Failures · Winch Drum ∅200, designed interference 0.18mm, measured 0.07mm · ★★★

Problem Symptom

The insufficient interference made the drum slip under the lifting shock, and control of the suspended load was lost

Root Cause

[Mechanism] The insufficient interference let the drum creep and slip under the shock torque.
[Calculation] The required p≥2T/(πd²Lμ)=2×14e3/(π×0.2²×0.25×0.12)=18.7MPa, but the measured δ=0.07 gives p=7.4MPa, which is insufficient.
[Design Omission] No tangent key was provided and the interference was not controlled; this design flaw caused the slip.

Correct Solution

1) Raise the interference to 0.18~0.22;
2) Add tangent keys;
3) Select H7/u6;
4) Hot assemble the bore part to guarantee the interference;
5) Check the rotation angle;
6) Carry out NDT after assembly to check for cracks;
7) Re-tighten periodically;
8) Carry out a pull-out test on the first piece.

Checklist

References

GB/T 5371-2004 Interference Fits — Calculation and Selection