Insufficient Centrifuge Drum-to-Shaft Interference Causes Vibration and Cracking

E43-197 · Interference Fit Failures · Centrifuge Drum ∅150, designed interference 0.12mm, measured 0.05mm · ★★★

Problem Symptom

The insufficient interference made the drum micro-move at high speed and destroy the dynamic balance, and the vibration stress cracked the drum

Root Cause

[Mechanism] The insufficient interference let the drum move radially and destroy the dynamic balance, and the superimposed vibration stress cracked it.
[Calculation] δ≥0.10 is needed to steady the drum; the measured 0.05 gives p=0.05×2.1e5/150=70MPa, which is insufficient and allowed micro-motion.
[Design Omission] The interference was not controlled and no dynamic balancing was done; this design flaw caused the cracking.

Correct Solution

1) Raise the interference to 0.12~0.15;
2) Dynamically balance to G1;
3) Select H7/t6;
4) Cold assemble the shaft part to guarantee the interference;
5) Measure the vibration velocity ≤2.8mm/s;
6) Carry out NDT after assembly to check for cracks;
7) Re-tighten periodically;
8) Carry out an overspeed test on the first piece.

Checklist

References

GB/T 5371-2004 Interference Fits — Calculation and Selection