E43-010 · Wrong Transition Fit Selection · Motor-Pump Coupling · ★★
Alignment deviation 0.15mm; vibration 4.2mm/s (allowable 1.8); 8 line stops per month
[Flange Bore Fit] The coupling flange and shaft were specified H7/k6, a transition fit on the loose side; interference tended to zero and after tightening the shaft-end radial runout was 0.12mm.
[Alignment Amplification] The non-coaxiality of the two coupling halves added up, imposing an additional bending moment on the pump shaft and raising vibration by a factor of 2.3.
[Design Omission] High-speed couplings should use a tight H7/js6 transition fit or heated assembly to guarantee zero clearance, and no dynamic balancing or alignment was carried out.
1) Change the coupling flange to a tight H7/js6 transition fit and assemble heated to guarantee concentricity;
2) Laser-align to bring the deviation ≤0.05mm and prevent uneven loading;
3) Dynamically balance the coupling to G2.5 to reduce vibration;
4) Finish-grind the shaft end to runout ≤0.01mm to preserve rotational accuracy;
5) Tighten the bolts with a torque wrench in a diagonal sequence to prevent uneven clamping;
6) Fit an intermediate diaphragm to accommodate slight misalignment and damp vibration;
7) Measure vibration ≤1.8mm/s during the trial run to verify smooth running;
8) Record the alignment data in the installation report for traceability.
GB/T 12458-2017 Couplings — Classification