E43-011 · Wrong Transition Fit Selection · Spindle Bearing Preload Structure · ★★
Bearing clearance fluctuated by 0.02mm; fast temperature rise and loud noise; 12 parts reworked per month
[End Cap Fit] The bearing outer ring and the end-cap spigot were specified H7/js6; fluctuation in the assembled interference changed the axial preload by 30%.
[Preload Instability] Preload variation made the clearance drift between -0.01 and +0.01, generating heat at high speed.
[Design Omission] Adjustable shims should be provided to control preload and the spigot should use H7/h6 for location; a transition fit is unsuitable for a preload structure.
1) Change the end-cap spigot to an H7/h6 locating fit with no interference, which eases assembly and disassembly;
2) Add adjustable shims to control preload accurately;
3) Calibrate preload by the torque method or displacement method to prevent over-tightening;
4) Control clearance at 0.005~0.01mm to secure bearing life;
5) Provide temperature measuring points on the bearing housing to monitor the temperature rise;
6) Re-check shim thickness with a feeler gauge after assembly to prevent errors;
7) Measure temperature rise ≤25℃ in the trial run to verify;
8) Write the preload process into the assembly card to standardise the operation.
GB/T 307.3-2017 Rolling Bearings — General Technical Rules