E43-057 · Wrong Transition Fit Selection · Machining Center Fixture · ★★
H7/k6 was designed but H7/h6 clearance was used; the locating pin moved 0.05mm, so parts were machined out of position and scrapped
[Wrong Fit] An H7/k6 transition fit with slight interference was required for location, but an H7/h6 clearance fit was used, allowing the pin to move.
[Location Drift] The 0.05mm clearance between pin and hole produced an angular error Δθ=δ/L, so the hole positions shifted.
[Design Omission] A two-pin-one-face location scheme with a transition fit should have been used, and no location error calculation was performed.
1) Change the locating pin to an H7/k6 transition fit to guarantee centring;
2) Use a two-pin-one-face location scheme to constrain the degrees of freedom;
3) Flatten one pin to avoid over-constraint interference;
4) Keep pin-to-hole coaxiality ≤0.01mm to preserve accuracy;
5) Calculate the angular error from Δθ=δ/L;
6) Inspect the pins for wear periodically to prevent accuracy degradation;
7) Verify the fixture repeatability accuracy;
8) Re-match out-of-specification pins.
GB/T 1801-2009 Limits and Fits