Coupling Transition Fit Causes Alignment Drift

E43-058 · Wrong Transition Fit Selection · Water Pump Coupling · ★★

Problem Symptom

H7/js6 was designed but an H7/g6 clearance was used; alignment drifted 0.08mm, causing heavy vibration and bearing failure

Root Cause

[Wrong Fit] An H7/js6 transition fit was required for even load sharing, but an H7/g6 clearance fit was used, allowing the shaft to move slightly.
[Alignment Drift] The clearance made the coupling eccentric by e=0.08mm, and at speed n the unbalanced force F=m e (2πn/60)² grew sharply.
[Design Omission] A transition fit plus a set screw should have been used, and neither axial location nor alignment was controlled.

Correct Solution

1) Change the coupling to an H7/js6 transition fit to ease assembly and disassembly;
2) Add set screws to prevent circumferential loosening;
3) Laser-align to ≤0.05mm to prevent uneven loading;
4) Use a shaft-end shoulder for axial location and prevent axial migration;
5) Dynamically balance to reduce vibration;
6) Calculate the unbalanced force from F=meω²;
7) Re-align periodically to prevent offset;
8) Reassemble out-of-specification parts.

Checklist

References

GB/T 12458-2017 Couplings