E43-059 · Wrong Transition Fit Selection · Pressure Vessel Flange · ★★★
H7/m6 was designed but an H7/h6 clearance was used; the flange relied on the bolts in shear, causing leakage twice
[Wrong Fit] An H7/m6 transition fit was required so the flange faces located against each other, but an H7/h6 clearance fit was used, so the bolts carried the shear load.
[Shear] With clearance present, the internal pressure thrust P=πD²p/4 was carried entirely in bolt shear and the shear stress exceeded the limit.
[Design Omission] A transition fit should carry the shear load and the bolts should be checked; no sealing face location was designed.
1) Change the flange to an H7/m6 transition fit to guarantee centring;
2) Finish machine the flange faces so they seat properly and prevent leakage;
3) Design the bolts for tension rather than shear so that they carry the load properly;
4) Check the bolt strength from P=πD²p/4;
5) Use a spiral wound gasket to compensate for unevenness and guarantee sealing;
6) Distribute the bolt torque evenly to prevent uneven loading;
7) Verify with a gas tightness test that there is no leakage;
8) Rework out-of-specification flanges.
GB/T 150-2011 Pressure Vessels