E43-401 · Transition Fit Selection Error · reducer gear bore ø50 selected H7/k6 transition with shaft, design should be H7/p6 interference transmitting 280N·m · ★★★
Wrong transition fit between gear and shaft caused circumferential slip 0.5° under impact load, pitting on tooth flanks.
[Mechanism] Transition fit has insufficient minimum interference; when torque exceeds its transfer capacity, gear slips relative to shaft.
[Calculation] Required min interference δ_min=2T/(π·d·l·μ·E)=2×280000/(π×50×60×0.12×2.1e5)≈0.0236mm; H7/k6 max interference only 0.018mm<δ_min, transfer failed.
[Design Omission] Heavy-duty gear wrongly chosen transition fit, design defect → circumferential slip.
1) Change heavy-duty gear to H7/p6 or H7/r6 interference fit for transfer;
2) Check fit minimum interference ≥1.5x δ_min;
3) Add key as double insurance for torque transfer;
4) Control shaft-bore roughness Ra≤1.6 to preserve μ;
5) Calculate press-fit force per interference;
6) Select high-grade tolerance for stable interference;
7) Torque sensor monitors slip;
8) First-article torsion test verifies no slip.
GB/T 1800.2-2020 Geometrical Product Specifications (GPS) — Limits and fits