E43-405 · Transition Fit Selection Error · housing bore ø110 with bearing outer ring selected H7/js6 transition, design should be H7/k6 light interference · ★★★

Problem Description

Bearing outer ring crept in housing bore, housing bore scored, abnormal temperature rise.

Root Cause

[Mechanism] Outer-ring transition fit has excessive clearance; under rotating outer-ring conditions outer ring creeps in housing bore and wears.
[Calculation] js6 limit clearance +0.017mm, outer-ring radial load causes creep increasing with clearance; should take k6 light interference -0.005~-0.03.
[Design Omission] Rotating outer-ring condition wrongly chosen loose transition, design defect → outer-ring creep.

Corrective Solution

1) Rotating outer ring change to H7/k6 or H7/m6 light interference;
2) Housing bore roughness Ra≤1.6;
3) Axial stop against rotation;
4) Control wall-thickness uniformity;
5) Select stable tolerance band;
6) Temperature monitoring;
7) Periodic housing-bore inspection;
8) First-article temperature ≤70℃.