E43-406 · Transition Fit Selection Error · worm wheel bore ø60 selected H7/k6 transition, design should be H7/p6 transmitting 350N·m · ★★★
Worm wheel transition fit wobbled 0.1mm under impact, tooth surface scuffing.
[Mechanism] Transition fit has insufficient interference; worm wheel under alternating axial and tangential forces wobbles.
[Calculation] δ_min=2×350000/(π×60×55×0.12×2.1e5)≈0.0168mm; k6 min interference 0 unstable causing wobble.
[Design Omission] Heavy-duty worm wheel wrongly chosen transition fit, design defect → wheel wobble.
1) Change worm wheel to H7/p6 interference;
2) Add roll screw against wobble;
3) Verify against δ_min;
4) Control surface roughness;
5) Calculate press-fit force;
6) Select a stable tolerance grade;
7) Wobble tester inspection;
8) First-article mesh test verifies no wobble.
GB/T 10089-2018 Cylindrical worm gearing — Accuracy