Knowledge Base › Tolerance and Fit Error Case › Cam Transition Fit Causing Phase Drift

Cam Transition Fit Causing Phase Drift

E43-407 · Transition Fit Selection Error · cam bore ø30 selected H7/js6 transition, design should be H7/p6 for phase · ★★★

Problem Description

Cam transition fit fretting made phase drift 2°, mechanism action disordered.

Root Cause

[Mechanism] Cam relies on interference to set phase; transition fit has unstable interference causing fretting phase offset.
[Calculation] Phase drift θ=Δα/r=2×π/180×30/2≈0.52mm arc length (measured 2°), from insufficient interference.
[Design Omission] Phase-sensitive part wrongly chosen transition fit, design defect → phase drift.

Corrective Solution

1) Change cam to H7/p6 interference locating;
2) Add pin against rotation;
3) Check interference per δ_min;
4) Control surface roughness;
5) Press-fit to set phase;
6) Select a stable tolerance grade;
7) Phase gauge inspection;
8) First-article action verifies phase ≤0.5°.

Checklist

Reference

GB/T 1800.2-2020 Geometrical Product Specifications (GPS) — Limits and fits