Knowledge Base › Tolerance and Fit Error Case › Pump Impeller-Shaft Transition Fit Slippage

Pump Impeller-Shaft Transition Fit Slippage

E43-416 · Transition Fit Selection Error · water pump impeller ø45 with shaft selected H7/k6 transition, design should be H7/p6 torque transfer · ★★

Problem Description

Impeller transition fit slipped, flow dropped 20%, insufficient head.

Root Cause

[Mechanism] Impeller relies on interference for torque transfer; transition fit insufficient interference slips and flow drops.
[Calculation] δ_min=2×T/(π·d·l·μ·E)=2×80000/(π×45×40×0.12×2.1e5)≈0.0112mm; k6 unstable.
[Design Omission] Pump impeller wrongly chosen transition fit, design defect → slip.

Corrective Solution

1) Change impeller to H7/p6 interference;
2) Add a key to prevent slipping;
3) Verify against δ_min;
4) Control surface roughness;
5) Calculate press-fit force;
6) Select a stable tolerance grade;
7) Flow and head monitoring;
8) First-article performance test verifies.