Knowledge Base › Tolerance and Fit Error Case › Fan Impeller Transition Fit Causing Dynamic Balance Loss

Fan Impeller Transition Fit Causing Dynamic Balance Loss

E43-417 · Transition Fit Selection Error · fan impeller ø300 with shaft selected H7/js6 transition, design should be H7/p6 interference · ★★★

Problem Description

Impeller transition fit fretting destroyed dynamic balance, vibration over limit.

Root Cause

[Mechanism] Impeller relies on interference to preserve dynamic balance; transition fit unstable interference fretting destroys balance.
[Calculation] Unbalance U=m·e grows, e=0.04mm makes U exceed G6.3 grade; δ_min≈0.015mm; js6 can be zero.
[Design Omission] High-speed fan impeller wrongly chosen transition fit, design defect → balance loss.

Corrective Solution

1) Change impeller to H7/p6 interference;
2) Heat-shrink positioning;
3) Verify against δ_min;
4) Control surface roughness;
5)Dynamic balanceG6.3;
6) Select a stable tolerance grade;
7) Vibration monitoring;
8) First-article dynamic balance verification.

Checklist

Reference

GB/T 1236-2017 Industrial fans - Standardized airways performance testing