Knowledge Base › Tolerance and Fit Error Case › Measuring Spindle Transition-Fit Error

Measuring Spindle Transition-Fit Error

E43-432 · Transition Fit Selection Error · CMM spindle ø20 with wheel selected H7/js6 transition, should be H7/p6 to maintain rotation · ★★★

Problem Description

Fretting from the measuring-spindle transition fit caused 0.01mm measurement error and unstable readings.

Root Cause

[Mechanism] The measuring spindle needs interference to maintain running accuracy; unstable transition-fit interference frets and creates error.
[Calculation] Error Δ=2e=2×0.005=0.01mm (eccentricity e); δ_min≈0.003mm; js6 can be zero.
[Design Omission] The measuring spindle was wrongly given a transition fit; design defect → measurement error.

Corrective Solution

1) Change the spindle to H7/p6 interference;
2) Add a pin to prevent rotation;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit positioning;
6) Select a stable tolerance grade;
7) Recheck indicator reading;
8) First-article error measured ≤0.005mm.