Indexing Disk Transition-Fit Index Error

E43-433 · Transition Fit Selection Error · Indexing disk ø80 with shaft selected H7/k6 transition, should be H7/p6 to maintain indexing · ★★★

Problem Description

Fretting from the indexing-disk transition fit caused 30″ index error and wrong workpiece angles.

Root Cause

[Mechanism] The indexing disk relies on interference to set angle; unstable transition-fit interference frets and shifts indexing.
[Calculation] Index error Δ=π·D·Δθ/360, δ_min=2T/(π·d·l·μ·E)≈0.01mm; k6 can be zero.
[Design Omission] The indexing disk was wrongly given a transition fit; design defect → index error.

Corrective Solution

1) Change the indexing disk to H7/p6 interference;
2) Add a taper pin to prevent rotation;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit positioning;
6) Select a stable tolerance grade;
7) Dividing-head instrument check;
8) First-article indexing measured ≤15″.

Checklist

Reference

GB/T 1800.2-2020 Geometrical Product Specifications (GPS) — Limits and fits