E43-442 · Transition Fit Selection Error · Valve stem ø20 with packing box selected H7/k6 transition, should be clearance H8/f8 · ★★

Problem Description

The valve stem was wrongly given a transition fit, causing sticking and high operating torque.

Root Cause

[Mechanism] The valve stem needs a clearance fit for freedom of movement; a transition fit with no clearance causes sticking.
[Calculation] Required clearance Xmin≥0.03mm; the k6 limiting clearance of 0.002 is insufficient → sticking.
[Design Omission] The valve stem was wrongly given a transition fit; design defect → sticking.

Corrective Solution

1) Change the stem to H8/f8 clearance;
2) Leave clearance for temperature rise;
3) Control surface roughness;
4) Select a stable tolerance grade;
5) Adjust packing preload properly;
6) Design for lubrication;
7) Operate torque trial;
8) First-article torque measured ≤ rated.

Checklist

Reference

GB/T 12224-2015 Steel valves — General requirements