E43-443 · Transition Fit Selection Error · Traction sheave ø400 with shaft selected H7/k6 transition, should be H7/p6 to transmit torque · ★★★

Problem Description

Slip under the traction-sheave transition fit made the rope speed deviate and leveling inaccurate.

Root Cause

[Mechanism] The traction sheave relies on interference to transmit torque; insufficient transition-fit interference causes slip.
[Calculation] δ_min=2×T/(π·d·l·μ·E)=2×800/(π×60×100×0.12×2.1e5)≈0.0034mm (note T=800N·m); k6 is unstable.
[Design Omission] The traction sheave was wrongly given a transition fit; design defect → slip.

Corrective Solution

1) Change the sheave to H7/p6 interference;
2) Add a key to prevent slip;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit verification;
6) Select a stable tolerance grade;
7) Leveling monitoring;
8) First-article load test verification.

Checklist

Reference

GB/T 24478-2009 Elevator traction machines