E43-444 · Transition Fit Selection Error · Hoisting drum ø110 with shaft selected H7/k6 transition, should be H7/p6 to transmit torque · ★★★
Slip under the drum transition fit made rope-length metering inaccurate and positioning deviate.
[Mechanism] The drum relies on interference to transmit torque; insufficient transition-fit interference causes slip.
[Calculation] δ_min=2×T/(π·d·l·μ·E)=2×700000/(π×110×90×0.12×2.1e5)≈0.018mm; k6 max 0.018 is borderline and unstable.
[Design Omission] The drum was wrongly given a transition fit; design defect → slip.
1) Change the drum to H7/p6 interference;
2) Add a tangential key;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit verification;
6) Select a stable tolerance grade;
7) Rope-length monitoring;
8) First-article load verification.
GB/T 1955-2019 Construction winches