E43-445 · Transition Fit Selection Error · Centrifuge basket ø500 with shaft selected H7/js6 transition, should be H7/p6 interference · ★★★
Fretting from the basket transition fit destroyed dynamic balance and caused vibration exceeding limits.
[Mechanism] The basket relies on interference to hold dynamic balance; unstable transition-fit interference frets and causes unbalance.
[Calculation] Unbalance U=m·e, e=0.05mm exceeds G2.5 grade; δ_min≈0.02mm; js6 can be zero.
[Design Omission] The centrifuge basket was wrongly given a transition fit; design defect → unbalance.
1) Change the basket to H7/p6 interference;
2) Heat-shrink positioning;
3) Verify against δ_min;
4) Balance to G2.5;
5) Press-fit positioning;
6) Select a stable tolerance grade;
7) Vibration monitoring;
8) First-article dynamic balance verification.