Compressor Crankshaft Pulley Transition-Fit Loosening

E43-446 · Transition Fit Selection Error · Compressor crankshaft ø60 with pulley selected H7/k6 transition, should be H7/p6 · ★★

Problem Description

The pulley loosened and slipped under the transition fit, reducing displacement.

Root Cause

[Mechanism] The crankshaft pulley relies on interference to transmit torque; insufficient transition-fit interference causes slipping.
[Calculation] δ_min=2×T/(π·d·l·μ·E)=2×200000/(π×60×55×0.12×2.1e5)≈0.0161mm; k6 is unstable.
[Design Omission] The compressor pulley was wrongly given a transition fit; design defect → loosening.

Corrective Solution

1) Change the pulley to H7/p6 interference;
2) Add a key to prevent slip;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit verification;
6) Select a stable tolerance grade;
7) Displacement monitoring;
8) First-article load verification.

Checklist

Reference

GB/T 1800.2-2020 Geometrical Product Specifications (GPS) — Limits and fits