E43-448 · Transition Fit Selection Error · Dryer ø1500 with shaft selected H7/js6 transition, should be H7/p6 to maintain runout · ★★★

Problem Description

Fretting from the dryer transition fit caused 0.2mm radial runout and uneven sheet thickness.

Root Cause

[Mechanism] The dryer relies on interference to hold running runout; unstable transition-fit interference frets and causes uneven sheet thickness.
[Calculation] Runout≈2e=2×0.1=0.2mm (eccentricity e); δ_min≈0.03mm; js6 can be zero.
[Design Omission] The paper dryer was wrongly given a transition fit; design defect → runout.

Corrective Solution

1) Change the dryer to H7/p6 interference;
2) Heat-shrink positioning;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit positioning;
6) Select a stable tolerance grade;
7) Runout meter inspection;
8) First-article runout measured ≤0.05mm.